MRI

Image acquisition

COMPASS-ND participants are scanned using the Canadian Dementia Imaging Protocol (CDIP). CDIP is organized around a central, tri-vendor (GE Healthcare, Philips Medical and Siemens Medical Systems MRI) harmonized core protocol of acquisitions. It is compressed to fit a 45-minutes window, which consists of six sequences:

  • 3D T1-weighted

  • T2/PD-weighted

  • FLAIR

  • T2*

  • Diffusion imaging

  • BOLD connectivity (resting state)

Prrovided below are the CDIP protocols for the:

3D T1-weighted scan

3D isotropic T1-weighted (T1w) imaging were obtained for assessing fine anatomical detail with high resolution (voxel size = 1.0 × 1.0 × 1.0 mm3) and acceleration factor of 2 (GE: FSPGR; Philips: T1-TFE; Siemens: MP-RAGE).

MRI sites parameters

Site

Field Strength (T)

Voxel size (mm3)

Matrix size

Flip Angle

TE (s)

TR (s)

THE_OTTAWA_HOSPITAL_CIVIC

3

3

256x256

165

0.091

3

Civic_Hospital

3

3

256x256

165

0.091

3

UBC

3

3

256x256

90

0.1

3

UBC_MRI_Research_Centre

3

3

256x256

90

0.1

3

Hospital_Douglas

3

3

256x256

165

0.093

3

IRM_Quebec_-_Mailloux_-_3T

3

3

256x256

90

0.1

3

IRM_Quebec_-_Synase_-_3T

3

3

256x256

90

0.1

3

ST_JOSEPH_HAMILTON

3

3

256x256

125

0.085696

3

FOOTHILLS_Hospital

3

3

256x256

125

0.089792

3

CHUS_FLEURIMONT_Philips_3t

3

3

256x256

90

0.1

3

IUGM

3

3

256x256

165

0.093

3

Sunnybrook_Research_Institute

3

3

256x256

165

0.093

3

Robarts_Research_Institute

3

3

256x256

165

0.093

3

Robarts

3

3

256x256

165

0.093

3

Robarts-CFMM

3

3

256x256

165

0.093

3

3T_ROYAL_UNIVERSITY_HOSP

3

3

256x256

165

0.093

3

Toronto_Western

3

3

256x256

90

0.084544

3

Peter_S._Allen_MR_Research_Centre

3

3

256x256

165

0.093

3

WCMI_UPTOWN

3

3

256x256

142

0.086184

3.35

Resting-state Functional MRI (rsfMRI)

Functional T2*-weighted images are obtained using a blood-oxygen-level-dependent (BOLD) sensitive single-shot echo-planar (EPI) sequence on the GE Healthcare, Philips Medical or Siemens Medical Systems MRI scanners. During the rsfMRI acquisitions, no specific cognitive tasks are performed, and participants are instructed to keep their eyes open. No camera or physiological recordings are captured, as these equipments are not available at every site.

f-MRI sites parameters

Site

Field Strength (T)

Voxel size (mm3)

Matrix size

Flip Angle

TE (s)

TR (s)

Volumes

Scan slices order

Scan time (min)

THE_OTTAWA_HOSPITAL_CIVIC

3

3.5

64x64

70

0.03

2.11

250

sequential decreasing

8.79

Civic_Hospital

3

3.5

64x64

70

0.03

2.11

250

sequential decreasing

8.79

UBC

3

3.5

64x64

70

0.030001

2.11

250

unknown

8.79

UBC_MRI_Research_Centre

3

3.5

64x64

70

0.03

2.11

250

unknown

8.79

Hospital_Douglas

3

3.5

64x64

70

0.03

2.13

250

sequential decreasing

8.88

IRM_Quebec_-_Mailloux_-_3T

3

3.5

64x64

70

0.030001

2.11

250

unknown

8.79

IRM_Quebec_-_Synase_-_3T

3

3.5

64x64

70

0.030001

2.11

250

unknown

8.79

ST_JOSEPH_HAMILTON

3

3.5

64x64

70

0.03

2.4

200

unknown

8.00

FOOTHILLS_Hospital

3

3.5

64x64

70

0.03

2.5

200

unknown

8.33

CHUS_FLEURIMONT_Philips_3t

3

3.5

64x64

70

0.03

2.11

250

unknown

8.79

IUGM

3

3.5

64x64

70

0.03

2.13

250

sequential increasing

8.88

Sunnybrook_Research_Institute

3

3.5

64x64

70

0.03

2.13

250

sequential increasing

8.88

Robarts_Research_Institute

3

3.5

64x64

70

0.03

2.13

250

sequential increasing

8.88

Robarts

3

3.5

64x64

70

0.03

2.13

250

sequential increasing

8.88

Robarts-CFMM

3

3.5

64x64

70

0.03

2.13

250

sequential increasing

8.88

3T_ROYAL_UNIVERSITY_HOSP

3

3.5

64x64

70

0.03

2.67

250

sequential decreasing

11.12

Toronto_Western

3

3.5

64x64

70

0.03

2.4

250

unknown

10.00

Peter_S._Allen_MR_Research_Centre

3

3.5

64x64

70

0.03

2.24

250

sequential increasing

9.33

WCMI_UPTOWN

3

3.5

64x64

70

0.03

2.5

250

unknown

10.42

Diffusion weighted MRI (DWI)

Diffusion weighted images are obtained by measuring the random Brownian motion of water molecules within a voxel of tissue.

DWI sites parameters

Site

Field Strength (T)

Voxel size (mm3)

Matrix size

TE (s)

TR (s)

b-values

Number of directions

Number of b0s

revb0

THE_OTTAWA_HOSPITAL_CIVIC

3

8

128x128

0.096

9.40

1000

30

1

none

Civic_Hospital

3

8

128x128

0.100

9.94

1000

32

1

none

UBC

3

8

128x128

0.100

9.93

1000

32

1

none

UBC_MRI_Research_Centre

3

8

128x128

0.096

9.40

1000

30

1

none

Hospital_Douglas

3

8

128x128

0.097

9.53

1000

32

1

none

IRM_Quebec_-_Mailloux_-_3T

3

8

128x128

0.097

9.53

1000

32

1

none

IRM_Quebec_-_Synase_-_3T

3

8

128x128

0.085

9.00

1000

30

3

none

ST_JOSEPH_HAMILTON

3

8

128x128

0.087

9.00

1000

30

3

none

FOOTHILLS_Hospital

3

8

128x128

0.109

10.44

1000

32

1

none

CHUS_FLEURIMONT_Philips_3t

3

8

128x128

0.064

6.90

1000

30

3

none

IUGM

3

8

128x128

0.064

6.90

1000

30

3

none

Sunnybrook_Research_Institute

3

8

128x128

0.064

6.90

1000

30

3

none

Robarts_Research_Institute

3

8

128x128

0.064

6.90

1000

30

3

none

Robarts

3

8

128x128

0.064

6.90

1000

30

3

none

Robarts-CFMM

3

8

128x128

0.101

13.00

1000

30

1

none

3T_ROYAL_UNIVERSITY_HOSP

3

8

128x128

0.106

11.70

1000

30

3

none

Toronto_Western

3

8

128x128

0.064

6.90

1000

30

3

none

Peter_S._Allen_MR_Research_Centre

3

8

128x128

0.083

12.50

1000

30

3

none

WCMI_UPTOWN

3

1

256x256

0.064

6.90

1000

30

1

none